System Performance System performance varies with lens focal length (F) and working distance (D) to the object. Edge, width, and center measurement accuracy are related to field of view at the object plane and specified as a fraction of the field of view. Using proprietary software, the HVS can meet the following accuracies even with significant variations in ambient lighting:
Edge measurement accuracy = FV/1000 Width measurement accuracy = FV/700 Center measurement accuracy = FV/1400
Dimensions

Specifications
Power (All Models) |
+11 to +15 VDC @ 350 mA max (700 mA with alignment light on) -11 to -15 VDC @ 150 mA max |
|
Outputs 256-XX3 |
State: Open collector NPN outputs with current sinking, 100 mA MAX, inductive load protection, MAX 30V |
256-XX5 256-XX6 |
Analog Voltage: 0 - 5 VDC or -5 to +5 VDC or 0 - 10 VDC Analog Current: 4 to 20 mA current loop |
Input/Output 256-13X 256-24X |
RS232C RS422/485 partyline (software addressable by serial number) |
Performance Repeatability Accuracy Resolution Range Measurement Rate Exposure Time |
1/2000th of the field of view 1/1000th of the field of view digital 1/500th of the field of view analog 1/4000th of the field of view 2-240 in (5.1-610 cm) Up to 5000/minute including calculated answers 0.25 to 999 milliseconds |
Physical Size Weight |
2.450 x 2.925 x 4.900 in (62.2 x 74.3 x 124.5 mm) 1.85 lbs with 25 mm lens (0.84 kg) |
Environmental Operating Temp. Storage Temp. Humidity NEMA Rating |
0 to 50º C -20 to 60º C Up to 95% non-condensing 12, 13 (4 optional) |
| Connector |
BURNDY BT02E12-14P military grade receptacle BURNDY BT06JF12-14S mating connector (included) |
| Test Conditions |
Minimum contrast 3:1 edge target Integration time 0.5-10 milliseconds |
|
 |
|
|
|