Industrial Equipment Gortite, Gortrac, MPC, SmartSkim, CecorIndustrial AutomationIndustrial Services

System Performance
System performance varies with lens focal length (F) and working distance (D) to the object. Edge, width, and center measurement accuracy are related to field of view at the object plane and specified as a fraction of the field of view. Using proprietary software, the HVS can meet the following accuracies even with significant variations in ambient lighting:

Edge measurement accuracy = FV/1000
Width measurement accuracy = FV/700
Center measurement accuracy = FV/1400

Dimensions



Specifications

Power
(All Models)

+11 to +15 VDC @ 350 mA max (700 mA with alignment light on)
-11 to -15 VDC @ 150 mA max
Outputs
256-XX3

State: Open collector NPN outputs with current sinking, 100 mA MAX, inductive load protection, MAX 30V
256-XX5
256-XX6
Analog Voltage: 0 - 5 VDC or -5 to +5 VDC or 0 - 10 VDC
Analog Current: 4 to 20 mA current loop
Input/Output
256-13X
256-24X

RS232C
RS422/485 partyline (software addressable by serial number)
Performance
Repeatability
Accuracy
Resolution
Range
Measurement Rate
Exposure Time

1/2000th of the field of view
1/1000th of the field of view digital
1/500th of the field of view analog
1/4000th of the field of view
2-240 in (5.1-610 cm)
Up to 5000/minute including calculated answers
0.25 to 999 milliseconds
Physical
Size
Weight

2.450 x 2.925 x 4.900 in (62.2 x 74.3 x 124.5 mm)
1.85 lbs with 25 mm lens (0.84 kg)
Environmental
Operating Temp.
Storage Temp.
Humidity
NEMA Rating

0 to 50º C
-20 to 60º C
Up to 95% non-condensing
12, 13 (4 optional)
Connector BURNDY BT02E12-14P military grade receptacle
BURNDY BT06JF12-14S mating connector (included)
Test Conditions Minimum contrast 3:1 edge target
Integration time 0.5-10 milliseconds

Click Here to Continue